Glass-Fiber-Reinforced Thermoset Resin Corrosion-Resistant. Tanks. View on Information Provider website {{ linkText }}. Abbreviation. ASTM D – ASTM D(). Standard Specification for Contact-Molded Glass-Fiber- Reinforced Thermoset Resin Corrosion-Resistant Tanks. ASTM D Standard Specification for Contact-Molded Glass-Fiber- Reinforced Thermoset Resin Corrosion-Resistant Tanks.

Author: Tojami Yora
Country: Colombia
Language: English (Spanish)
Genre: Music
Published (Last): 5 November 2012
Pages: 165
PDF File Size: 19.27 Mb
ePub File Size: 3.18 Mb
ISBN: 442-7-92916-136-2
Downloads: 81731
Price: Free* [*Free Regsitration Required]
Uploader: Mazuzuru

The tanks are classified as type I and II according to the operating pressure or vacuum levels, and the safety factor required for external pressure. Just two of the many ways Design Tanks rises above the fray without additional costs to our customers! This standard does not purport to address all of the safety concerns, if any, associated with its use.

It is the 44097 of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to e.

Included are requirements for materials, properties, design, construction, dimensions, tolerances, workmanship, and appearance. Work Item s – proposed revisions of this standard. For example, RTP-1 does not require a fabricator to keep materials in an environmentally controlled storage area prior to manufacturing. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

This specification does not cover the design of vessels intended for pressure above hydrostatic, vacuum conditions, except as classified herein, or vessels intended for use with liquids heated above their flash points. The result is a quality product with a very low incidence of tank failure.

  ALEJANDRO PAGLIARI PDF

The values given in parentheses are provided for information purposes only. While Design Tanks has elected not to seek certification at this time, atm meet and exceed many of the RTP-1 standards without the additional costs associated with certification. The resin used shall be a commercial grade, corrosion-resistant thermoset.

Design Tanks stores resins in a climate-controlled storage area to eliminate production variances related to temperature changes. There is no known ISO equivalent to this standard.

The Design Tanks Difference: Exceeding The Standards | Design Tanks

Includes requirements for materials, properties, design, construction, dimension, tolerance, workmanship, and appearance. Materials shall be tested and the individual grades shall conform to specified values of design requirements such as straight shell, external pressure, top head, bottom head, open-top tanks, joints, fittings, hold-down lugs, and lifting lugs; laminate construction requirements such as structural tank, joints, and fittings and accessories; and other requirements such as physical properties, chemical resistance of resin, glass content, tensile strength, flexural properties and degree of cure.

The tanks are further classified as grade 1 and 2 according to the generic types of thermoset resin. What are Design Tanks manufacturing standards? As a custom manufacturer specializing in meeting the unique needs of our customers, our exposure to these different standards is much higher than for the manufacturer that produces a cookie cutter tank.

The reinforcement should be a chopped-strand mat, a nonwoven biaxial or unidirectal fabric, a woven roving, or a surface mat. Applies to manufacturing standards for Design Tanks contact-molded small- and medium-sized tanks.

S fabricators can provide an RTP-1 stamp on qualifying tanks. This specification covers cylindrical tanks fabricated by contact molding for above-ground vertical installation, to contain aggressive chemicals at essentially atmospheric pressure, and made of a commercial-grade polyester or vinyl ester, resin.

  EQUIVALENCE OF DFA AND NDFA PDF

All tanks are designed by an in-house professional engineer for design purposes, including a detailed QC program and a QC lab to keep tank production according to RTP-1 standards.

The three predominant standards today that relate to fiberglass tanks and vessels are: We build a heavier, more robust tank that always exceeds the standard for wall thickness.

It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. Design Tanks complies with the design strength requirements of ASTM Dutilizing a rigorous in-line and end-of-line quality control process plus testing of all resins and incoming materials.

Link to Active This link will always route to the current Active version of the standard.

Resources & News

The dimensions and tolerances, as well as the workmanship, finish and appearance are also detailed. The Design Tanks Difference: The customer receives a tank that exceeds the standard! Referenced Documents purchase separately The ast listed below are referenced within the subject standard but are not provided as part of the standard.

Historical Version s – view previous versions of standard. ASME RTP-1 As a custom manufacturer specializing in meeting the unique needs of our customers, our exposure to these different standards is much higher than for the manufacturer that produces a cookie cutter tank.