BODET MASTER CLOCK SYSTEM PDF

Learn more about Bodet Sigma Mod Master Clock’s specifications and and other systems; Automatic resetting of time distribution after power shortage; Clock . SYNCHRONISED CLOCK SYSTEMS The European Leader in Time first phase in time distribution where the master clock receives a very accurate time signal. Time distribution and relay programming through DHF radio and NTP on the all new bodet sigma Centrlized master clock system.

Author: Shakacage Dalmaran
Country: Honduras
Language: English (Spanish)
Genre: Art
Published (Last): 4 July 2009
Pages: 395
PDF File Size: 11.93 Mb
ePub File Size: 10.61 Mb
ISBN: 439-8-65276-811-5
Downloads: 60869
Price: Free* [*Free Regsitration Required]
Uploader: Akinolar

Synchronised, accurate time across your organisation using the best technology for your needs Bodet offers several types of Clock Systems. Open the catalog to page 4. Open the catalog to page 6. Get a free quote and advice from Bodet Register your enquiry. The clocks send alerts via the ethernet network. The alerts can be reviewed and the associated parameters can be set. With its satellite network the GPS system ensures time synchronisation anywhere in the world.

Wireless Clock Systems – Clocks & Clock Systems – Bodet

If you have many networked devices on an existing IT network or require pinpoint accuracy, we would recommend our Time Server. Impulse Time Distribution This technology is suitable for small installations where there is a limited number of slave clocks, and limited wiring distance.

Monday, 31 December Our licence free Sigma Software lets you configure mastre of these elements from a PC without needing to access settings on the Master Clock directly. Open the catalog to page 3.

The time message is sent either periodically Multicast or on demand Unicast. The GPS antenna receives a UTC Universal Time Coordinated time message and, if necessary, the master clock performs a time shift to match the time zone of its location.

  DESCARGAR LIBRO A LA CARGA GUNG HO PDF

This type of distribution is mainly used in large installations such as Airports and Railways where there are long distances between the slave clocks. A good reception of three satellites is sufficient bodt accuracy greater than one microsecond.

It can also control Bell Systems, and building systems such as lighting, heating and air conditioning. Time distribution Time distribution consists in synchronizing a network We also offer standalone clocks which can be synchronised individually.

Find out more OK.

With Impulse Time Distribution, a signal is sent through polarised impulses every minute, half minute or second. By continuing to browse this site, you agree to the use of cookies. Open the catalog to page 5.

Open the catalog to page 8. Depending on the number of clocks and the length of the line. Bodet offers several types of Clock Systems.

Wired Clock System

This provides a digital signal from the Master Clock. This technology is suitable for small installations where there is a limited number of slave clocks, and limited wiring distance. For a refurbishment or in an existing building, we recommend our new state-of-the art Wireless Clock System. A Master Clock is a c,ock unit able to transmit reliable, consistent time data to a network of clocks.

The Online Industrial Exhibition. Synchronises the computer network NTP time server. A wired alternative to Master Clocks are our Time Serverswhich allow you to send a time signal to additional masetr on a network, in addition to clocks.

BODET SIGMA CENTRALIZED MASTER CLOCK Supplier Qatar – Adax Business Systems

Monday, 31 December Open the catalog to page There are two different time distribution types which can be used with a Wired Clock System. Coded Time Distribution This type of distribution is mainly used in large installations such as Airports and Railways where there are long distances between the slave clocks. This provides a cost effective solution for small Clock Systems with analogue clocks. Controls the network of relays, bell systems and microphones.

  ICH HAB DIE UNSCHULD KOTZEN SEHEN LESEPROBE PDF

This can be provided either via a Master Clock, or a Time Server. With every clock and networked device across your organisation displaying exactly the same accurate time, you increase efficiency. A GPS system ensures accuracy by using a network of 24 satellites with global coverage. Master Clocks come with an antenna which can receive a radio signal, such as GPS.

Find out more OK. For a new building, either a Wired Clock System or a Wireless Clock System would be suitable, depending on your requirements. By continuing to browse this site, you agree to the use of cookies.

Computer network time distribution Connected to a computer network, the slave clocks receive an NTP time message from the master clock which is also connected to the network. Another option is NTP Network Time Protocola type of network protocol used to synchronise both clocks and additional devices across an existing data network.

Time Management Solutions The monitored time distribution operates Up to 30 km 50 clocks max. Time Management Solutions